missing translation for 'onlineSavingsMsg'
Learn More

Gibco™ CTS™ Detachable Dynabeads™ CD3/CD28 Kit

Código de producto. p-200000101
Click to view available options
Cantidad:
Kit grande
Kit pequeño
Tamaño de la unidad:
cada uno
Este artículo no se puede devolver. Vea la política de devoluciones

Código de producto. 17846158

Marca: Gibco™ A56992

Por favor, para comprar este producto. ¿No tiene usuario web? Regístrese hoy mismo.

Este artículo actualmente no está disponible o ha sido discontinuado.
Ver la página del producto para posibles alternativas
Ver productos alternativos

Este artículo no se puede devolver. Vea la política de devoluciones

The Gibco CTS Detachable Dynabeads CD3/CD28 Kit is intended for ex vivo isolation and activation of T cells in a simultaneous one-step mechanism.

The Gibco CTS Detachable Dynabeads CD3/CD28 Kit is intended for ex vivo isolation and activation of T cells in a simultaneous one-step mechanism. As part of a next-generation platform, this offering is the first cGMP cell selection technology to have an active release mechanism for process development, clinical trial, and commercial manufacturing use.

Features of the CTS Detachable Dynabeads CD3/CD28 Kit include:
• Empowers users with process flexibility by allowing active release of beads from target cells at any time
• Optimizes target cell purity, yield, activation profile, and desired phenotype thanks to the active release mechanism that gives users more control
• Provides an automation-friendly solution by working directly with the CTS DynaCellect Magnetic Separation System
• Enables consistent performance in light of biological variability within processes
• Is suitable for both autologous and allogeneic cell therapy manufacturing processes

Coated with camelid-derived single-domain VHH antibodies that target CD3 and CD28 cell surface markers, these Dynabeads magnetic beads provide both the primary and co-stimulatory signals that are required for activation and expansion of T cells. An accompanying release buffer within the kit has an active ingredient, biotin, that competitively displaces a biotin derivative on the surface of the beads. This proprietary mechanism allows users to achieve active release of the beads from target cells at any time within their process.

Based on a recommended 3-to-1 bead-to-target-cell ratio (not total nucleated cell number), the smaller kit size can theoretically isolate and activate up to 1.33 x 109 T cells. The larger kit size can theoretically isolate and activate up to twice that number of cells.

The CTS Detachable Dynabeads CD3/CD28 Kit also includes Drug Master Files (DMFs) for each of its components to support cross-referencing in regulatory submissions prior to clinical trial and commercial manufacturing use.

TRUSTED_SUSTAINABILITY

Especificaciones

Contenido y almacenamiento • 10 mL CTS Detachable Dynabeads CD3/CD28 (1 vial)
• 400 mL CTS Detachable Dynabeads Release Buffer (1 bioprocess container)

Store at 2–8°C.

Color Brown
Material Poliestireno
Tipo de producto Cell Isolation and Activation Reagent
Cantidad Kit pequeño
Diámetro (métrico) 4.5 micron

Para su uso en investigación o fabricación de productos basados en células, genes o tejidos. PRECAUCIÓN: no diseñado para la administración directa en seres humanos o animales.

Corrección del contenido de un producto

Proporcione sus comentarios sobre el contenido del producto rellenando el siguiente formulario.

Título del producto

Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.

Gracias por ayudarnos a mejorar nuestra web. Su comentario ha sido enviado