Learn More
Cytiva Columnas preenvasadas HiScreen™ MabSelect™, Xtra™, SuRe™, SuRe LX™
Designed for method optimization and parameter screening for capture of monoclonal antibodies. Cytiva HiScreen™ MabSelect™, Xtra™, SuRe™, SuRe LX™ Prepacked Columns come ready-to-use for convenience.
Marca: Cytiva 28-9269-76
Descripción
- Ready-to-use columns for convenient process development
- Rigid, highly cross-linked agarose matrix
- Bed height of 10cm is designed to allow method optimization and parameter screening
- Easily connected in series to achieve 20cm bed height
- Small bed volume (4.7mL) gives fast result and minimal sample/buffer consumption
- Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity
MabSelect
- For capture of MAbs from large sample volumes
- Prepacked with protein A-derived media
- Compatible with high flow rates and high pressure when scaling up
- Increased binding capacity enables purification of MAbs from high-level expression feedstock
- Also optimized for Fc-fusion proteins
- Very low, unspecific binding due to high ligand selectivity and matrix hydrophilicity
- Prepacked with protein A-derived media
- With novel, alkali-tolerant recombinant protein A ligand that provides greater stability and allows use of 0.1 to 0.5M sodium hydroxide for cleaning-in-place (CIP)
- Enhanced protease resistance resulting in lower ligand leakage
- High dynamic binding capacity

Especificaciones
8M Urea, 6M Guanidine Hydrochloride, 2% Benzyl Alcohol or 20% Ethanol | |
Stoppers at the inlet and outlet | |
Filter | |
≈40mg Human IgG | |
HiScreen MabSelect Xtra Prepacked Column | |
10cm | |
Recombinant Protein A (E.coli) | |
Polypropylene | |
3bar | |
2° to 8°C |
HiScreen MabSelect Xtra Prepacked Column | |
1 x 4.7mL | |
0.3 in. | |
0.77cm | |
3.93 in. | |
Designed for method optimization and parameter screening for capture of monoclonal antibodies | |
Epoxy Activation | |
75μm | |
3 to 10 | |
Column |
Sugerencias de productos
Customers who viewed this item also viewed.
Seguridad y manipulación
- HiScreen MabSelect Xtra
Palabra de advertencia
- Atención
Clasificación
- Líquido inflamable Categoría 3
Indicaciones de peligro
- H226-Líquidos y vapores inflamables.
Consejos de prudencia
- P210-Mantener alejado del calor, de superficies calientes, de chispas, de llamas abiertas y de cualquier otra fuente de ignición. No fumar.
- P501b-Eliminar el contenido/el recipiente en conforme a la reglamentación local/regional/nacional/internacional.
Otros peligros
- MIXTURE LIST-Contém: ethanol
Proporcione sus comentarios sobre el contenido del producto rellenando el siguiente formulario.